Which kit do I need?

Three questions decide it.

1. What connector is on your VNA?

  • SMA or 3.5mm ports (NanoVNA, LibreVNA, most USB VNAs, Keysight and R&S 3.5mm instruments): a 3.5mm kit. 3.5mm standards mate with SMA and are mechanically more consistent, which is why we use them.
  • Type N ports (many bench VNAs, antenna and cable work): a Type N kit.
  • A LibreVNA or another VNA with electronic calibration support: consider LibreCAL. One USB-C module replaces the Open, Short, Load and Thru shuffle on up to four ports.

2. What gender is the device you are measuring?

The calibration standards stand in for your device at the reference plane, so the kit gender matches the DUT's connector, not the VNA port. A device with a male connector needs a male kit; a device with a female connector needs a female kit. The gender of your VNA port and cables does not matter: whatever you connect the kit to is where the DUT will go.

If you measure devices of both genders, such as cables (male ends) and board-mounted connectors (female), you want both, which is what the male and female kits are for.

3. Which tier?

The accuracy of a calibration is driven mainly by the quality of the data files that describe the standards, and every VNA Lab kit gets the same measurement: each standard is individually swept on a VNA calibrated with a genuine Keysight 85052C precision kit. A Base kit is characterised to exactly the same standard as a Precision kit.

What changes between tiers is the quality of the parts themselves. Better connectors keep their characteristics for more mating cycles, so the data stays valid for longer, and the loads have tighter return-loss specifications.

  • Base: individually measured standards at the lowest cost. The load is not specified to a return-loss figure; its data file tells you exactly what you have. Ideal for NanoVNA and LibreVNA users and anyone calibrating occasionally.
  • Economy: higher-grade parts that will last longer, with loads specified better than 36 dB return loss to at least 6 GHz. The tier most working engineers should buy.
  • Precision: the highest-grade parts, loads better than 40 dB to at least 9 GHz, phase-matched adapters and a torque wrench. For daily use and measurements that go in a report.

Should I add the 20 GHz measurement upgrade?

If your VNA goes past 8.5 GHz, yes. The standards are physically usable well beyond their specified range; the upgrade replaces the 8.5 or 9 GHz data set with one measured to 20 GHz, so your VNA can error-correct to 20 GHz with the same kit.

Should I add a verification standard?

Always a good idea, especially with a new VNA. The SMA verification load buys you the ability to prove your calibration is doing what you think it is.

Three tiers, one method

Base Economy Precision
Who it's for NanoVNA, LibreVNA, hobby and teaching labs Working engineers, small labs, universities Daily use; when the measurement is the deliverable
Characterisation Individually measured, Keysight 85052C reference Same Same
Part quality and life Standard Higher Highest
Connectors 3.5mm M or F 3.5mm M, F or both; Type N M or F 3.5mm M and F
Load return loss Individually measured, data supplied Better than 36 dB to 6 GHz Better than 40 dB to 9 GHz
Data supplied to 8.5 GHz 8.5 GHz 9 GHz
Touchstone and polynomial models Included Included Included
Phase-matched adapters - Optional Included
Torque wrench - Optional Included
20 GHz data upgrade Available Available Available
From (NZD) $150 $399 $4,250

Still not sure? Contact us with your VNA model and what you are measuring. You will get a straight answer, not an upsell.